Home Directory

Search Exchange

Search All Sites

Nagios Live Webinars

Let our experts show you how Nagios can help your organization.

Contact Us

Phone: 1-888-NAGIOS-1
Email: sales@nagios.com

Login

Remember Me

Directory Tree

Directory

Patrick

Reviews(1)
check_cciss - HP and Compaq Smart Array Hardware status
The -p switch seems to not work. How can I fix this? I'd like to get the status of physical disks in the output. I've added -p to my command but still getting the same result like -v without the status of physical disks.

./check_cciss-1.11 -v
RAID CRITICAL - HP Smart Array Failed: Smart Array P400 in Slot 1 Controller Status: OK Cache Status: Temporarily Disabled Battery/Capacitor Status: Failed (Replace Batteries/Capacitors)

./check_cciss-1.11 -v -p
RAID CRITICAL - HP Smart Array Failed: Smart Array P400 in Slot 1 Controller Status: OK Cache Status: Temporarily Disabled Battery/Capacitor Status: Failed (Replace Batteries/Capacitors)
Owner's reply

Hello Patrick,
use the "-p" (detail for physical drives) with the "-v" (status and informations about RAID).
Regards