Search Exchange

Search All Sites

Nagios Live Webinars

Let our experts show you how Nagios can help your organization.

Contact Us

Phone: 1-888-NAGIOS-1
Email: sales@nagios.com

Login

Remember Me

Directory Tree

Disks on IBM Servers

Current Version
1.1
Last Release Date
2012-02-11
Compatible With
  • Nagios 3.x
Owner
Hits
84843
Files:
FileDescription
check_snmp_ibm_storage.shcheck_snmp_ibm_storage.sh
Nagios CSP

Meet The New Nagios Core Services Platform

Built on over 25 years of monitoring experience, the Nagios Core Services Platform provides insightful monitoring dashboards, time-saving monitoring wizards, and unmatched ease of use. Use it for free indefinitely.

Monitoring Made Magically Better

  • Nagios Core on Overdrive
  • Powerful Monitoring Dashboards
  • Time-Saving Configuration Wizards
  • Open Source Powered Monitoring On Steroids
  • And So Much More!
Disks on IBM Servers
Check the storage area on IBM Servers
$ ./check_snmp_ibm_storage.sh

Check hardware storage on IBM server with SNMP - Version 1.0

usage: ./check_snmp_ibm_storage.sh [ -H value -C value -h ]

syntax:

-H --> Host - Name or IP Address
-C --> Community SNMP (default public)
-h --> Print This Help Screen


Required the ServeRAID or MegaRAID LSI package.
Check your controller, find correct package in IBM site and install it.


2013 September: upload new version with a little fix.
Now, the LSI controller is detected correctly.
Reviews (1)
bynishith, December 19, 2012
1 of 1 people found this review helpful
./check_snmp_ibm_storage.sh -H -C public
OK - Storage Overall Status is not detected ["Adaptec" "IBM ServeRAID 8k" Ver. "5.2-0

Memory: 256 MB on battery [Status ok]
Status controller is ok [controller overall status is ok]

Drive 1 is ok - "controller 1, enclosure 0, slot 0" [Vendor "IBM-ESXS" Model "VPBA146C3ETS11 N" FW "A496" - Serial "JFVGDBVC"] Capacity 140013 - Smart value is ok

Drive 2 is ok - "controller 1, enclosure 0, slot 1" [Vendor "IBM-ESXS" Model "VPBA146C3ETS11 N" FW "A496" - Serial "JFVJ6D5C"] Capacity 140013 - Smart value is ok

Drive 6 is ok - "controller 1, enclosure 0, slot 5" [Vendor "IBM-ESXS" Model "GNA300C3ESTT0Z N" FW "BH0G" - Serial "J802YTYK"] Capacity 286102 - Smart value is ok

Array 1 is ok [State quickInited] - raid1 with capacity 139900 - Task Status: noTaskActive at 100 % [Priority task is low]

Array 2 is ok [State optimal] - raid5 with capacity 858000 - Task Status: noTaskActive at 100 % [Priority task is low]