Home Directory Plugins Hardware Server Hardware Lenovo Check Lenovo SMM (System Management Module)

Search Exchange

Search All Sites

Nagios Live Webinars

Let our experts show you how Nagios can help your organization.

Contact Us

Phone: 1-888-NAGIOS-1
Email: sales@nagios.com

Login

Remember Me

Directory Tree

Check Lenovo SMM (System Management Module)

Rating
0 votes
Favoured:
0
Current Version
1.0
Last Release Date
2019-02-22
Compatible With
  • Nagios 4.x
Owner
License
GPL
Hits
5476
Files:
FileDescription
check_lenovo_smm.pycheck_lenovo_smm.py
Nagios CSP

Meet The New Nagios Core Services Platform

Built on over 25 years of monitoring experience, the Nagios Core Services Platform provides insightful monitoring dashboards, time-saving monitoring wizards, and unmatched ease of use. Use it for free indefinitely.

Monitoring Made Magically Better

  • Nagios Core on Overdrive
  • Powerful Monitoring Dashboards
  • Time-Saving Configuration Wizards
  • Open Source Powered Monitoring On Steroids
  • And So Much More!
This is a Nagios plugin (python script) that monitors Lenovo SMM (System Management Module) through IPMI protocol. This Lenovo Nagios plugin can collect hardware informations of the following components: voltage, cooling, psu, nodes, power and psu_fan.
**System Requirements**
* Hardware Requirement
Lenovo SMM (System Management Module)

* Software Requirement
python2.7 or python3.5
ipmitool

* Output
power module:
```
$ ./check_lenovo_smm.py -H 198.126.XX.XX -u USER_NAME -p PASSWORD -m power
OK - System: "Lenovo ThinkSystem SD530 Server"; MTM: "xxxxxxxx"; SN: "xxxxxxxx"; | Enclosure Power Min.=50W; Enclosure Power Avg.=50W; Enclosure Power Max.=51W;

Enclosure Power: Min.:50W Avg.:50W Max.:51W
```
Nodes:
```
$ ./check_lenovo_smm.py -H 198.126.XX.XX -u USER_NAME -p PASSWORD -m nodes
OK - System: "Lenovo ThinkSystem SD530 Server"; MTM: "xxxxxxxx"; SN: "xxxxxxxx"; 4 out of 4 Nodes is OK; | Node1 Power Consumption(Avg.)=41W; Node2 Power Consumption(Avg.)=5W; Node3 Power Consumption(Avg.)=0W; Node4 Power Consumption(Avg.)=5W;

Node1 IP address:198.126.xx.xx Status:Power ON
Node2 IP address:198.126.xx.xx Status:Power OFF
Node3 IP address:198.126.xx.xx Status:Power ON
Node4 IP address:198.126.xx.xx Status:Power OFF
Node1 Power Consumption: Min.(W):40 Avg.(W):41 Max.(W):41
Node2 Power Consumption: Min.(W):5 Avg.(W):5 Max.(W):5
Node3 Power Consumption: Min.(W):N/A Avg.(W):0 Max.(W):N/A