The components checked for failures and/or operation outside the normal range are CPUs, power supplies, fans, temperatures and memory modules.
The latest release also checks IML log events for memory errors during POST. These are very dangerous: “Memory initialization error… The OS may not have access to all of the memory installed in the system”
nagios:~> check_hpasm
CRITICAL - dimm module 2 @ cartridge 2 needs attention (dimm is degraded)
nagios:~> check_hpasm -v
checking hpasmd process
System :proliant dl580 g3
Serial No. :GB8632FB7V
ROM version :P38 04/28/2006
checking cpus
cpu 0 is ok
cpu 1 is ok
cpu 2 is ok
cpu 3 is ok
checking power supplies
powersupply 1 is ok
powersupply 2 is ok
checking fans
checking temperatures
cpu#1 temparature is 36 (80 max)
cpu#2 temparature is 34 (80 max)
cpu#3 temparature is 33 (80 max)
cpu#4 temparature is 37 (80 max)
i/o_zone temparature is 32 (60 max)
ambient temparature is 23 (40 max)
system_bd temparature is 34 (60 max)
checking memory modules
dimm 1@1 is ok
dimm 2@1 is ok
dimm 3@1 is ok
dimm 4@1 is ok
dimm 1@2 is ok
dimm 2@2 is dimm is degraded
dimm 3@2 is ok
dimm 4@2 is ok
CRITICAL - dimm module 2 @ cartridge 2 needs attention (dimm is degraded)
check_hpasm --hostname bladec1 -v
CRITICAL - power supply 1:1:1 is present, condition is failed (Ser: 5AXXD0AHLY403L, FW: ) (SparePartNum 500242-001), power supply 1:1:2 is present, condition is failed (Ser: 5AXXD0AHLY403Y, FW: ) (SparePartNum 500242-001), power supply 1:1:3 is present, condition is failed (Ser: 5AXXD0AHLY403W, FW: ) (SparePartNum 500242-001), common enclosure KDZ-BC3 condition is degraded (Ser: GB1147A1WH, FW: 2.60) (SparePartNum 519345-001), power enclosure 1:1 'SDF-BC3' condition is degraded, System: 'bladesystem c7000 enclosure g2', S/N: 'GB1147A1WH'
common enclosure SDF-BC3 condition is degraded (Ser: GB1147A1WH, FW: 2.60)
fan 1:1:1 is present, location is 1, redundance is other, condition is ok
fan 1:1:10 is present, location is 10, redundance is other, condition is ok
fan 1:1:2 is present, location is 2, redundance is other, condition is ok
fan 1:1:3 is present, location is 3, redundance is other, condition is ok
fan 1:1:4 is present, location is 4, redundance is other, condition is ok
fan 1:1:5 is present, location is 5, redundance is other, condition is ok
fan 1:1:6 is present, location is 6, redundance is other, condition is ok
fan 1:1:7 is present, location is 7, redundance is other, condition is ok
fan 1:1:8 is present, location is 8, redundance is other, condition is ok
fan 1:1:9 is present, location is 9, redundance is other, condition is ok
power enclosure 1:1 'SDF-BC3' condition is degraded
power supply 1:1:1 is present, condition is failed (Ser: 5AXXD0AHLY403L, FW: )
power supply 1:1:1 status is generalFailure, inp.line status is linePowerLoss
power supply 1:1:2 is present, condition is failed (Ser: 5AXXD0AHLY403Y, FW: )
power supply 1:1:2 status is generalFailure, inp.line status is linePowerLoss
power supply 1:1:3 is present, condition is failed (Ser: 5AXXD0AHLY403W, FW: )
power supply 1:1:3 status is generalFailure, inp.line status is linePowerLoss
power supply 1:1:4 is present, condition is ok (Ser: 5AXXD0AHLY403M, FW: )
power supply 1:1:5 is present, condition is ok (Ser: 5AXXD0AHLY404O, FW: )
power supply 1:1:6 is present, condition is ok (Ser: 5AXXD0AHLY403N, FW: )
net connector 1:1:1 is present, model is HP HP VC Flex-10 Enet Module (Ser: TW294123TF, FW: )
net connector 1:1:2 is present, model is HP HP VC Flex-10 Enet Module (Ser: TW294123TL, FW: )
net connector 1:1:3 is present, model is HP HP VC 8Gb 24-Port FC Module (Ser: CN8921D08D, FW: )
net connector 1:1:4 is present, model is HP HP VC 8Gb 24-Port FC Module (Ser: CN8921D087, FW: )
server blade 1:1:1 'linuxbl1' is present, status is value_unknown, powered is value_unknown
server blade 1:1:9 'linuxbl2' is present, status is value_unknown, powered is value_unknown
The latest release also checks IML log events for memory errors during POST. These are very dangerous: “Memory initialization error… The OS may not have access to all of the memory installed in the system”
nagios:~> check_hpasm
CRITICAL - dimm module 2 @ cartridge 2 needs attention (dimm is degraded)
nagios:~> check_hpasm -v
checking hpasmd process
System :proliant dl580 g3
Serial No. :GB8632FB7V
ROM version :P38 04/28/2006
checking cpus
cpu 0 is ok
cpu 1 is ok
cpu 2 is ok
cpu 3 is ok
checking power supplies
powersupply 1 is ok
powersupply 2 is ok
checking fans
checking temperatures
cpu#1 temparature is 36 (80 max)
cpu#2 temparature is 34 (80 max)
cpu#3 temparature is 33 (80 max)
cpu#4 temparature is 37 (80 max)
i/o_zone temparature is 32 (60 max)
ambient temparature is 23 (40 max)
system_bd temparature is 34 (60 max)
checking memory modules
dimm 1@1 is ok
dimm 2@1 is ok
dimm 3@1 is ok
dimm 4@1 is ok
dimm 1@2 is ok
dimm 2@2 is dimm is degraded
dimm 3@2 is ok
dimm 4@2 is ok
CRITICAL - dimm module 2 @ cartridge 2 needs attention (dimm is degraded)
check_hpasm --hostname bladec1 -v
CRITICAL - power supply 1:1:1 is present, condition is failed (Ser: 5AXXD0AHLY403L, FW: ) (SparePartNum 500242-001), power supply 1:1:2 is present, condition is failed (Ser: 5AXXD0AHLY403Y, FW: ) (SparePartNum 500242-001), power supply 1:1:3 is present, condition is failed (Ser: 5AXXD0AHLY403W, FW: ) (SparePartNum 500242-001), common enclosure KDZ-BC3 condition is degraded (Ser: GB1147A1WH, FW: 2.60) (SparePartNum 519345-001), power enclosure 1:1 'SDF-BC3' condition is degraded, System: 'bladesystem c7000 enclosure g2', S/N: 'GB1147A1WH'
common enclosure SDF-BC3 condition is degraded (Ser: GB1147A1WH, FW: 2.60)
fan 1:1:1 is present, location is 1, redundance is other, condition is ok
fan 1:1:10 is present, location is 10, redundance is other, condition is ok
fan 1:1:2 is present, location is 2, redundance is other, condition is ok
fan 1:1:3 is present, location is 3, redundance is other, condition is ok
fan 1:1:4 is present, location is 4, redundance is other, condition is ok
fan 1:1:5 is present, location is 5, redundance is other, condition is ok
fan 1:1:6 is present, location is 6, redundance is other, condition is ok
fan 1:1:7 is present, location is 7, redundance is other, condition is ok
fan 1:1:8 is present, location is 8, redundance is other, condition is ok
fan 1:1:9 is present, location is 9, redundance is other, condition is ok
power enclosure 1:1 'SDF-BC3' condition is degraded
power supply 1:1:1 is present, condition is failed (Ser: 5AXXD0AHLY403L, FW: )
power supply 1:1:1 status is generalFailure, inp.line status is linePowerLoss
power supply 1:1:2 is present, condition is failed (Ser: 5AXXD0AHLY403Y, FW: )
power supply 1:1:2 status is generalFailure, inp.line status is linePowerLoss
power supply 1:1:3 is present, condition is failed (Ser: 5AXXD0AHLY403W, FW: )
power supply 1:1:3 status is generalFailure, inp.line status is linePowerLoss
power supply 1:1:4 is present, condition is ok (Ser: 5AXXD0AHLY403M, FW: )
power supply 1:1:5 is present, condition is ok (Ser: 5AXXD0AHLY404O, FW: )
power supply 1:1:6 is present, condition is ok (Ser: 5AXXD0AHLY403N, FW: )
net connector 1:1:1 is present, model is HP HP VC Flex-10 Enet Module (Ser: TW294123TF, FW: )
net connector 1:1:2 is present, model is HP HP VC Flex-10 Enet Module (Ser: TW294123TL, FW: )
net connector 1:1:3 is present, model is HP HP VC 8Gb 24-Port FC Module (Ser: CN8921D08D, FW: )
net connector 1:1:4 is present, model is HP HP VC 8Gb 24-Port FC Module (Ser: CN8921D087, FW: )
server blade 1:1:1 'linuxbl1' is present, status is value_unknown, powered is value_unknown
server blade 1:1:9 'linuxbl2' is present, status is value_unknown, powered is value_unknown
Reviews (9)
byshehan88, October 15, 2015
Excellent Plugin, I integrated it with nagios and snmp. I hope this will save someone's time
http://www.tectut.com/2015/10/setup-nagios-check_hpasm-for-hp-servers/
http://www.tectut.com/2015/10/setup-nagios-check_hpasm-for-hp-servers/
bymkoco, September 23, 2015
Best plugin for checking HP hardware.
byjonlar, July 17, 2013
One of the best nagios plugins imo!
Is there a posibility to get the snmp check of the plugin to work with solaris and windows machines aswell?
Is there a posibility to get the snmp check of the plugin to work with solaris and windows machines aswell?
byxens, March 6, 2012
Hello, very good plugin. Had trouble to install hp-health on my server (no package management like RPM or APT) but after that the plugin works very well.
byduxklr, September 6, 2011
Excellent plugin. It does exactly what it says it should. We are using it to do hardware testing on HP DL360 G7's with no problems. Remote SNMP is enabled. Here is a quick guide to getting the minimum amount of HP software installed to make this Nagios plugin work: https://wiki.zweck.net/doku.php?id=hpservers
byalfred, July 13, 2011
great plugin, i use it for DL380G7 and DL180G6 with ubuntu 10.04 x64
thank you for that plugin!
thank you for that plugin!
Great plug-in, with good documentation (should do more developers), and serious error trapping.
I'm really happy wit it for monitoring my HP Proliant hardware.
Steven
I'm really happy wit it for monitoring my HP Proliant hardware.
Steven
All checks (Memory, Fans, Temp System, CPU & Memory), are working in Nagios 3. Graphs are working in Centreon 2 too.
Just great.
Just great.
We have used this plugin for years on all of our ~200 HP servers running Red Hat Linux. The plugin is detailed and accurate whenever it discovers a problem, and I can recommend this to anyone looking to monitor the hardware health of HP servers.